Refcomp SRC-S(W)-463 SRC-S-463-L4 R407C Screw Refrigertion Compressor

Basic Properties
Place of Origin: China
Brand Name: Refcomp
Certification: CE
Model Number: SRC-S(W)-463,SRC-S-463-L4
Trading Properties
Minimum Order Quantity: 1
Price: Discussed
Payment Terms: T/T,Western Union
Supply Ability: 100000Pcs/Year
Specifications
Refrigerant: R22, R407C, R404A,R507 Horse Power: 160HP/120KW
Voltage: 400V/3/50Hz-460V/3/60Hz Energy regulation: 100%,75%,50%,25%(stepless 100%-25%)
Application: HVAC,Cold Room,Condensing Unit,Air Conditioning Displacement 50/60Hz: 510/612 M³/hr
High Light:

Refcomp SRC-S-463 R407C screw compressor

,

SRC-S(W)-463 refrigeration compressor

,

R407C screw refrigeration compressor with warranty

Product Description
Refcomp SRC-S(W)-463 SRC-S-463-L4 R407C Screw Refrigeration Compressor
Product Description
  • Precision Rotor Profile: Advanced asymmetrical rotor geometry delivers exceptional volumetric efficiency and smooth compression for this screw refrigeration compressor.
  • High-Efficiency Oil Separation: Built-in multi-stage oil separator reaches up to 99.85% efficiency, minimizing oil carryover and maintaining system heat exchange capacity.
  • Robust Bearing Structure: Heavy-duty angular contact and thrust bearings support high mechanical loads, ensuring long-term continuous reliability.
  • Flexible Load Adaptation: Supports step capacity regulation at 100%, 75%, 50%, and 25%, as well as stepless control down to 25% to match varying system cooling loads.

Product Image
Refcomp SRC-S Screw Compressor unit showing industrial design and connections

Technical Parameters
Model SRC-S(W)-463 SRC-S-463-L4
Standard Motor Power 160HP/120KW
Displacement (50/60Hz) 510/612 m³/h
Weight 775KG
Oil Charge 16L
Cooling Capacity Regulation 100%, 75%, 50%, 25% (stepless 100%-25%)
Electrical Heater 275W-230V-50/60Hz
Standard Motor 400/3/50Hz-460/3/60Hz
LRA Y/Δ 374/1155A 453/1333A
Technical diagram of Refcomp SRC-S screw compressor components

Frequently Asked Questions
Q: What details are required when selecting this screw refrigeration compressor for a new refrigeration plant?
A: Selection requires confirming the required cooling capacity, evaporating and condensing temperatures, target refrigerant, and project electrical power specifications.
Q: What piping considerations are essential during installation?
A: Ensure precise connection to the 80.0 mm discharge and 105.5 mm suction ports, provide rigid pipe anchoring to reduce vibration, and verify discharge check valve positioning to prevent liquid return on shutdown.
Q: What pre-commissioning checks must be performed prior to starting the compressor?
A: Check that the 16 dm³ oil charge is visible in the sight glass, verify proper signal wiring to the INT69 SNY protection module, and ensure the crankcase heater has energized for sufficient pre-heating time.
Q: What routine maintenance practices ensure stable continuous operation?
A: Inspect the internal suction filter for pressure drop, monitor oil differential pressure across internal flow channels, and check motor thermal protection circuits during periodic maintenance.